Monday, November 2, 2015

boiler mounting major parts


Mounting  major parts of auxiliary boiler1.main steam stop valve
2.Two  safety valvs
3.Two gauge  glass
4.Feed check valve (none return type)
5.Air vent cock
6.Automatic feed water  regulator
7.Scum blow down valve(none return type)
8.Bottom blow down vale
9.salinometer cock /sampling cock
10.Men hole door
11.Mud hole door
12.Pressure gauge
13.Root valve for level indicator
14.Root valve for pressure gauge glass
15.Circulating  pump suction valve
16.Soot blower
17.low level alarm chamber
18.If super heater then need drain valve.
  Safety valve:   
To prevent/protect  the boiler  from over pressure .
#It release out steam more then 10%set pressure.
    BLOW DOWN VALVE:
A valve which enable water to be blow down  completely